How to Read a Chinese Cable Designation: YJV, YJV22, KVV, WDZC Explained

·

Single-core medium voltage XLPE cable with copper conductor and metallic screen

§01 — THE CODE

A Chinese cable designation reads left to right, and every letter changes something physical.

Most export buyers meet Chinese designations through a tender: YJV22 8.7/15 kV 3×240. The number part is easy. The letters carry the construction, and they are not decorative — each one changes what is inside the cable and how it behaves on site.

§02 — LETTER BY LETTER

The four positions that matter most.

PositionLetterMeaning
ИзоляцияY / V / ZY = XLPE, V = PVC, Z = flame-retardant (usually with a following code for the compound)
Conductor / filler(none) / TCopper is normally omitted; L = aluminium conductor
Inner covering / screenV / FV = PVC sheath over the laid-up core; F = flexible variant for specific ranges
Броня22 / 23 / 32 / 422 = steel tape, 3 = steel wire, 4 = non-magnetic; the second digit is the outer sheath (2 = PVC, 3 = PE)

So YJV22 is XLPE insulated, PVC sheathed, steel-tape armoured. YJV23 is the same cable with a PE sheath — the right choice where the cable is buried in wet soil, because PE resists moisture better than PVC.

§03 — CONTROL AND LSZH

KVV and WDZC-KYJY decode differently.

Control cable uses K for control, then insulation, then shielding and armour: KVV is PVC/PVC, KVVP adds a braid screen (P for screened), KVVP2 a tape screen, KVV22 steel-tape armour.

Low-smoke halogen-free control cable reads as a sentence: W (no halogen) D (low smoke) Z (flame-retardant) C (C category per the bunched test) — then K control, YJ XLPE insulated, Y PE sheath. That is WDZC-KYJY, the cable our type-test report covers.

The designation never tells you the voltage class — that is always written separately as U₀/U, e.g. 8.7/15 kV.

§04 — FAQ

Is YJV22 the same as SWA cable?

Not exactly. YJV22 is steel-tape armour (STA), which is what most buyers actually need for direct burial. Steel-wire armour (SWA) is YJV32 or YJV33. Many enquiries ask for SWA when the specification really describes STA.

What does the second digit in 22 / 23 mean?

The outer sheath material: 2 = PVC, 3 = polyethylene. PE sheathing is the better choice in wet or termite-prone ground.

Where does the aluminium conductor show up?

As an L after the insulation letter: YJLV22 is the aluminium version of YJV22. Copper is the default and is left out of the code.

Next step

Send us the specification and we will check it against IEC 60502-2.

Voltage class, cores, conductor material, armour type, cross-section and destination port — that is everything we need to come back with a drawing, a datasheet and a drum plan.