MEDIUM VOLTAGE · 3.6 / 6 kV · IEC 60502-2

Кабель XLPE 6 кВ

Industrial plants, mine feeders and substation auxiliary power at the 3.6/6 kV class. Three-core or single-core construction, copper or aluminium conductor, manufactured against IEC 60502-2 with project-specific screen sizing, armour and sheath.

Cu / Al класс 23-core & single coreSTA · SWA · AWA25–630 mm²PD ≤ 10 pC
ТипCU/XLPE/CWS/STA/PVC
U₀/U (Uₘ)3.6 / 6 kV (7.2 kV)
ИзоляцияXLPE, 2.5 mm nominal
Metallic screenCu wire screen per IEC 60502-2
БроняSTA (SWA / AWA optional)
ОболочкаPVC ST2 black (PE / LSZH optional)
Routine voltage testAC 12.5 kV / 5 min
Partial discharge≤ 10 pC at 6.2 kV (1.73 U₀)
Impulse (type test)60 kV
Single-core XLPE MV construction - studio view - Lulian Cable product view
Single-core XLPE MV construction – studio view

§01 — Cable construction

The reference construction, layer by layer.

At 3.6/6 kV the electrical stress in the XLPE wall is modest, so the wall is only 2.5 mm nominal — the mechanical package (core forming, bedding, armour) dominates the design. Mine and plant feeders on this class usually specify STA armour for direct burial and SWA where tensile load or rodent risk is high. Screen cross-section is selected against the earth-fault current and clearing time of the network, and confirmed against the cable schedule before production.

Technical data — reference only. Figures in the tables below are reference values for early-stage project comparison. Conductor size, insulation and sheath thickness, overall diameter, DC resistance and ampacity are confirmed against the approved cable schedule and the applicable standard (IEC 60502-2 / GB/T 12706) before production. Ampacity is quoted for installation in free air at 40 °C ambient; ratings for buried, in-conduit or tray installation differ. Dimensional and electrical tolerances follow the relevant standard.
#СлойReference detail
01ЖилаCu class 2 stranded (RM). Sector-shaped (SM) for 3-core ≥ 185 mm².
02Conductor screenExtruded semiconducting compound, ≤ 0.5 mm nominal thickness.
03Изоляция XLPEExtruded XLPE, 2.5 mm nominal at 3.6/6 kV (up to 3.2 mm for conductors of 500 mm² and above) per IEC 60502-2, table 6.
04Insulation screenExtruded semiconducting, strippable or bonded per requirement.
05Metallic screenCu wire screen sized to the network earth-fault current: 16 mm² minimum for conductors up to 120 mm², 25 mm² for 150–300 mm², 35 mm² for 400–630 mm².
06Inner sheathPVC ST2, extruded bedding.
07БроняDouble steel tape (STA) for direct burial; SWA for higher tensile load; AWA for single-core.
08ServingAnti-corrosion wrap on certain designs (optional).
09Outer sheathPVC ST2 black; PE or LSZH on request.
Single-core 6kV class medium voltage cable with copper conductor, metallic screen and wire armour
6kV single-core armoured construction

§02 — Technical specifications

Electrical parameters — 3.6 / 6 kV class.

Conductor (mm² Cu)Insulation thicknessDC resistance @20 °C (Ω/km)Indicative current, direct burial 25 °C (A)
3 × 352.5 mm0.524~170
3 × 502.5 mm0.387~205
3 × 702.5 mm0.268~250
3 × 952.5 mm0.193~300
3 × 1202.5 mm0.153~345
3 × 1502.5 mm0.124~385
3 × 1852.5 mm0.0991~435
3 × 2402.5 mm0.0754~500
3 × 3002.5 mm0.0601~560
3 × 4002.5 mm0.0470~640

DC resistance values per IEC 60228. Indicative current: ground 25 °C, soil thermal resistivity 1.5 K·m/W, depth 1.0 m, flat formation — reference only; final ampacity is calculated against your installation conditions. Overall diameter and weight for this voltage class are issued in the project datasheet with the formal offer.

§02B — Worked example · 3.6 / 6 kV

Voltage drop on a 1.2 km mine feeder.

Take a 3 × 95 mm² Cu feeder, 1.2 km, 150 A load current, power factor 0.85. With R = 0.193 Ω/km (IEC 60228) and an assumed reactance of ≈ 0.09 Ω/km for this construction, ΔU ≈ √3 · I · L · (R cos φ + X sin φ) ≈ 65 V — about 1.1% of 6 kV, comfortably inside the usual 5% design limit. We re-run this calculation with your actual route length, formation and conductor material before confirming the cross-section; the final figure is stated in the project datasheet.

§03 — Standards

Standards printed on the sheath and on the drum card.

IEC 60502-2GB/T 12706.2BS 6622BS 7835 (LSZH)IEC 60332-3CIEC 61034-2IEC 60754-1/2EN 50575 CPRICEA S-10634

§05 — Quality testing

What we test on every drum.

Routine tests run on every drum; sample tests on each batch; type tests on new constructions witnessed by CNAS-accredited third-party labs.

  • Conductor DC resistance at 20 °C (routine)
  • AC voltage withstand AC 12.5 kV / 5 min (routine)
  • Partial discharge ≤ 10 pC at 6.2 kV (1.73 U₀) (sample)
  • Insulation thickness & eccentricity (sample)
  • Metallic screen cross-section (routine)
  • Armour coverage & bedding integrity (routine)
  • Sheath thickness + spark test (routine)
  • Bending test + voltage after bending (type)
  • Impulse voltage 60 kV (type)
Routine electrical testing of medium voltage cable in the Lulian in-house laboratory
Routine electrical test · in-house lab

§06 — Packaging & delivery

Drums sized for the cable, not for the workshop.

For mine feeders we plan the drum schedule around shaft and gallery headroom — shorter drum lengths and lifting arrangements are agreed at order stage, with the minimum bending radius preserved on every drum. Wooden drums with fumigation marks for export; steel-plywood drums for heavy cross-sections. Cable ends sealed with heat-shrink caps; shipping marks per the buyer’s format.

Standard drum lengths: 500 / 1000 / 1500 / 2000 m. Lead time: 25–35 working days for stocked constructions; 40–55 working days for project-specific builds.

§07 — FAQ

Common questions on 6 kV cable procurement.

What is the U₀/U rating of 6 kV XLPE cable?

3.6 / 6 kV, with Uₘ = 7.2 kV. It covers 6.0 kV and 6.6 kV nominal systems whose maximum operating voltage stays within 7.2 kV. Send the earthing arrangement — solid, resistance or isolated neutral — and we confirm the class and the screen design together.

What conductor cross-sections are available?

Three-core: 25–400 mm². Single-core: 25–630 mm². Copper or aluminium, class 2 stranded; sector-shaped conductors for large 3-core sizes.

Can the cable be direct-buried?

Yes. The armoured construction (STA) with PVC ST2 outer sheath is rated for direct burial. SWA is recommended where tensile load or rodent risk is high.

What is the partial discharge limit?

≤ 10 pC measured at 6.2 kV (1.73 U₀) per IEC 60502-2. PD is measured on every drum and documented on the routine test report.

What routine and type tests are performed?

Routine on every drum: conductor DC resistance, AC voltage withstand AC 12.5 kV / 5 min, sheath spark test. Sample: PD, insulation thickness, screen check. Type: bending + voltage, load cycle, impulse voltage 60 kV.

Can the cable be supplied with LSZH sheath?

Yes, for tunnel, metro, data centre and indoor substation use. Verified against IEC 61034 (smoke density) and IEC 60754 (acid gas).

Is the 6 kV cable suitable for a 6.6 kV system?

Yes. A 6.6 kV nominal system has a phase-to-earth voltage of 3.81 kV and a maximum operating voltage below the 7.2 kV ceiling of the 3.6/6 class. We confirm the assignment against your earth-fault factor before order confirmation.

Пришлите кабельную ведомость. Подтверждаем конструкцию за 24 часа.

Share voltage class, conductor material & size, core count, armour, sheath, installation method, total length and drum preference.

Запрос по email → sales@luliancable.comОткрыть форму запроса

Напряжение (U₀/U)3.6 / 6 kV
ЖилаCu / Al класс 2
Cross-section3 × 185 mm² (typical)
БроняSTA / SWA / AWA
ОболочкаPVC ST2 · black
СтандартIEC 60502-2
ИнкотермFOB Циндао · CIF [порт]