CONTROL CABLE · 450/750 V · GB/T 9330 · IEC 60227

KVV / KVVP Control Cable — the nervous system of the panel.

Multicore control and signalling cable for switchgear, automation panels and fixed industrial routes: KVV unscreened, KVVP with copper-braid screen, KVV22 with steel-tape armour. 2–61 cores, 0.75–10 mm².

450/750 V2–61 cores0.75–10 mm²Cu braid screen (KVVP)STA option (KVV22)

§01 — Product family

Four constructions, one system voltage.

Technical data — reference only. Figures in the tables below are reference values for early-stage project comparison. Conductor size, insulation and sheath thickness, overall diameter, DC resistance and ampacity are confirmed against the approved cable schedule and the applicable standard (GB/T 9330 / IEC 60245) before production. Ampacity is quoted for installation in free air at 40 °C ambient; ratings for buried, in-conduit or tray installation differ. Dimensional and electrical tolerances follow the relevant standard. LSZH (WDZC-KYJY) variants in this family are verified by third-party test report No. 202521001018 to GB/T 9330-2020.
النوعدرع / تسليحUse
KVVNoneControl circuits inside panels, trays and dry indoor routes
KVVPCopper-braid screenEMI-sensitive control and measurement loops near drives and power cables
KVVP2Copper-tape screenHigher screening coverage for instrument-grade loops
KVV22Steel-tape armourDirect burial and mechanically exposed control runs
KVVP shielded control cable with copper braid screen, 1 to 6 mm² cores
KVVP shielded control cable · 1–6 mm² · factory photo
التركيب

What is inside

Copper class 1 (or class 5 flexible) conductors → PVC insulation with numbered cores → optional copper braid or tape screen → PVC outer sheath. Flame-retardant (ZR-KVV) and LSZH (WDZC-KYJY) variants share the same core.

For LSZH control cable with published type test, see the WDZC-KYJY LSZH control cable page.

§02 — Reference parameters

Core counts and sizes.

البندRange
الجهد المقنن450/750 V
عدد النوى2, 3, 4, 5, 7, 10, 12, 14, 19, 24, 27, 30, 37, 44, 48, 52, 61
Cross-section0.75 / 1.0 / 1.5 / 2.5 / 4 / 6 / 10 mm²
الموصلCopper class 1 (solid) or class 5 (flexible, KVVR)
العزل / الغمدPVC 70 °C · XLPE / LSZH variants available
DC resistance example1.5 mm² ≤ 12.1 Ω/km · 2.5 mm² ≤ 7.41 Ω/km (IEC 60228)
Voltage test3000 V / 5 min, no breakdown (routine)
StandardsGB/T 9330 · IEC 60227 · flame-retardant per IEC 60332-3

PRODUCT VIEWS

The range at a glance.

KVVP shielded multicore control cable - Lulian Cable product view
KVVP: overall copper braid screen.
Shielded multicore control cable - Lulian Cable product view
Numbered cores, 2 to 61 cores, 0.75 to 10 mm2.
KVV and KVVP control cable product range - Lulian Cable
KVV unscreened / KVVP screened variants.

§03 — FAQ

Common questions on control cable.

When do we need KVVP instead of KVV?

Whenever the control loop runs parallel to power cables or near VFDs and soft starters: the copper-braid screen keeps induced noise out of measurement and interlocking signals. As a rule, analogue signals and safety interlocks get screened cable; simple 24 V DC switching in clean panels can stay unscreened.

Control cable vs power cable — what is the actual difference?

Voltage class and duty, not size. Control cable is 450/750 V with many small cores for signalling and interlocking; power cable is 0.6/1 kV and above with few large cores for energy transfer. Running control signals on power cable (or vice versa) fails both inspection and EMC practice.

Do you have an LSZH control cable with a test report?

Yes — WDZC-KYJY 450/750 V passed a complete third-party type test (report No. 202521001018, GB/T 9330-2020): smoke transmittance 80 %, bunched flame class C, halogen-free. The measured values are published on the LSZH control cable page.

Can cores be numbered and colour-coded to our wiring diagram?

Numbered black cores are standard. Colour-coded cores and printing of the buyer’s circuit references on the sheath are available for project orders — include the wiring schedule with the RFQ.

أرسل جدول الكابلات. نؤكد خلال 24 ساعة.

Share conductor material & size, core count, armour, installation method, total length and destination port.

طلب عرض السعر بالبريد → sales@luliancable.comافتح نموذج RFQ

ذات صلة

ورقة بيانات

Download the datasheet.

Construction, test values and reference dimensions as a PDF — attach it to your enquiry or keep it in the project file.

Download Kvv Kvvp Control Cable datasheet (PDF)

أرسل استفسارًا

اطلب عرض سعر

ثلاثة حقول. رد فني خلال 24 ساعة.