FIRE-RESISTANT & MINERAL INSULATED · BTTZ / BTLY / BBTRZ · IEC 60331

Mineral Insulated & Fire-Resistant Cable — power that survives the fire.

Mineral-insulated and flexible fire-resistant cable for life-safety circuits: fire pumps, smoke extraction, emergency lighting and fire-alarm power. Circuit integrity verified against IEC 60331 and BS 6387.

BTTZ rigid MIBTLY flexible MIBBTRZ LSZH fire-resistant750 V class950 °C / 3 h rated
BTTZ rigid mineral-insulated fire-resistant cable with copper sheath - Lulian Cable product view
BTTZ rigid mineral-insulated cable – product view

§01 — Three constructions

Rigid, flexible, and LSZH — three ways to keep the circuit alive.

TipoConstrucciónCharacterUso típico
BTTZCopper conductors, compressed MgO insulation, seamless copper sheathRigid MI cable; fully inorganic — nothing to burnFire pumps, smoke extraction fans, highest-integrity circuits
BTLY (NG-A)Copper conductors, mineral composite insulation, corrugated copper sheathFlexible MI; much easier to install than rigid BTTZEmergency power risers in high-rise buildings
BBTRZMineral-insulated core with LSZH outer coveringFlexible, low-smoke halogen-free fire-resistantTunnels, metros, hospitals — fire + smoke requirements together
Mineral insulated fire-resistant cable: smooth copper sheath BTTZ type and corrugated sheath BTLY type
BTTZ & BTLY mineral insulated cable · factory photo
PATENTED

Own mineral-insulated patent

Our mineral-insulated cable design is covered by a Chinese utility-model patent held by Shandong Lulian Cable — one of seven patents across fire-resistant, irradiated and mineral-insulated constructions.

Patent certificate shared with the formal offer.

§02 — Fire performance

What “fire-resistant” actually means on the test bench.

ClasificaciónNormaWhat it proves
Circuit integrity in fireIEC 60331-21Cable keeps working at 750 °C flame for 90 minutes minimum
Fire + water + mechanical shockBS 6387 C / W / Z650 °C fire, then water spray, then impact — circuit stays alive
Flame retardanceIEC 60332-1 / -3No flame propagation along the cable run
Smoke & halogen (BBTRZ)IEC 61034 / IEC 60754Low smoke, no corrosive halogen gas in escape routes
BTTZ constructionGB/T 13033 · BS EN 60702-1Mineral insulated cable dimensional and electrical conformity

MI cable rating: 950 °C / 180 min survival is the reference class for BTTZ construction; exact rating confirmed per construction with the formal offer.

PRODUCT VIEWS

The range at a glance.

Fire-resistant cable cutaway product view - Lulian Cable
Flexible fire-resistant cable, cutaway view.
Fire-resistant cable layered construction - Lulian Cable
Layered construction of the fire-resistant build.
Fire-resistant cable construction range comparison - Lulian Cable
BTTZ rigid MI vs BTLY flexible MI vs BBTRZ.

§03 — FAQ

Common questions on fire-resistant cable.

Fire-resistant vs flame-retardant — what is the difference?

Flame-retardant (ZR) cable resists catching fire and stops flames spreading — but it is not expected to keep working during a fire. Fire-resistant (NH / MI) cable keeps the circuit alive during the fire itself, typically 90–180 minutes at 750–950 °C. Life-safety circuits (fire pumps, smoke extraction, emergency lighting) need fire-resistant; general power circuits in escape routes need flame-retardant + LSZH.

BTTZ vs BTLY — which one should we specify?

BTTZ is the absolute top tier: fully inorganic, seamless copper sheath, the highest fire integrity — but rigid, harder to install and needs special terminations. BTLY (corrugated sheath) gives near-equivalent fire performance with far easier installation and longer factory lengths. Most high-rise emergency risers today specify BTLY/BBTRZ for this reason.

What sizes and voltages are available?

Rated 750 V (BTTZ class). Single core to 400 mm², multi-core 1.5–25 mm² typical; flexible types up to 4×95 mm² and beyond on request. Confirm the fire pump / fan load schedule with the RFQ and we size the cross-section.

Can fire-resistant cable be supplied with third-party witnessed tests?

Yes — SGS / BV / Intertek witnessed fire tests are arranged for project orders, and the routine test report ships with every drum.