FAMILIA DE PRODUCTO · IEC 60502-2 · GB/T 12706.2

Cable de media tensión 6–35 kV

XLPE-insulated medium voltage power cable manufactured in Liaocheng, China. We supply 6 kV through 35 kV — copper or aluminium conductor, single or three core, armoured or unarmoured — built against your project specification and type-tested as a complete construction.

Cu / Al clase 2Single & 3-coreSTA · SWA · AWA25–630 mm²Ensayo de tipo IEC 60502-2

§02 — Normas

Un cable, múltiples normas.

Designed against IEC 60502-2 and manufactured to GB/T 12706.2. British BS 6622, IEC 60332 flame-retardant and CPR-rated versions are produced against confirmed project specification. Standards printed on the sheath and drum card match what your inspector will check.

IEC 60502-2GB/T 12706.2BS 6622BS 7835 (LSZH)IEC 60332-3IEC 61034IEC 60754EN 50575 CPRICEA S-10634

§03 — Construcción del cable

Nueve capas, cada una con una función de ingeniería específica.

Buyers who specify MV cable by voltage alone often end up with the wrong cable. The metallic screen cross-section, insulation screen bonding method, bedding under the armour and longitudinal water-blocking are all decided at construction stage.

#CapaFunción
01Conductor trenzado clase 2 (Cu / Al)Transporta la corriente de carga. Redondo compacto (RM) estándar; sectorial (SM) para secciones grandes de 3 núcleos.
02Pantalla del conductor (capa semiconductora interna)Elimina huecos de aire en la superficie del conductor; evita la descarga parcial en la interfaz conductor/aislamiento.
03Aislamiento XLPEPolietileno reticulado triple extrusionado. 90 °C continuo, 250 °C cortocircuito (máx 5 s).
04Pantalla de aislamiento (capa semiconductora externa)Proporciona una superficie equipotencial lisa y superficie de unión para la pantalla metálica.
05Pantalla metálica (CWS / CTA)Lleva la corriente de fallo a tierra; sección dimensionada según IEC 60502-2 (típicamente ≥ 16 mm² Cu para 11 kV).
06Cubierta interna / rellenoRelleno para la armadura y barrera de humedad; estándar PVC ST2.
07Armadura (STA / SWA / AWA)Protección mecánica: STA para enterrado directo, SWA para carga de tracción alta, AWA para unipolar para limitar pérdida por corrientes parásitas.
08Servicio (opcional)Envoltura anticorrosión entre armadura y cubierta en ciertos diseños.
09Cubierta exterior (PVC ST2 / PE / LSOH)Resistencia a UV, humedad y abrasión. Estándar PVC ST2; PE ST7 para rutas largas enterradas directamente; LSOH para túneles e interiores.
Single-core medium voltage XLPE cable construction: conductor, semicon layers, XLPE insulation, copper tape screen, armour and outer sheath
Construcción mononuclear MV · vista real del producto

§04 — Cómo elegir

Tres preguntas deciden el cable correcto antes de pedir un precio.

01

¿Cuál es la tensión del sistema y el método de puesta a tierra?

The cable U₀ must be ≥ the system highest phase-to-earth voltage under all conditions including earth-fault. A 10 kV solidly-earthed system needs 6/10 kV cable (U₀ = 6 kV); the same 10 kV on an unearthed system may need 8.7/15 kV. Send the earth-fault factor with your inquiry.

02

¿Dónde discurrirá el cable, y qué cargas transportará?

El método de instalación (enterrado directo, conducto, bandeja, aéreo) decide armadura y cubierta. La corriente de carga, temperatura ambiente, resistividad térmica del suelo y agrupamiento deciden la sección del conductor requerida.

03

¿Unipolar o de tres núcleos?

El unipolar es estándar por encima de ~400 mm² y para clasificaciones de corriente mayores. El de tres núcleos es estándar para distribución de servicios públicos hasta 33 kV y la mayoría de los intakes industriales.

§05 — Manufacturing & testing

Procesos reales, no solo certificados.

Our MV extrusion line is triple-extrusion with dry-curing CCV. Routine tests are performed on every drum; sample tests and type tests run against IEC 60502-2 at our in-house laboratory, witnessed by CNAS-accredited third-party labs for new constructions.

Insulation extrusion line — cable core passing through the extruder head
In-house extrusion line · Liaocheng, Shandong
Tensile test machine and measuring bench in the Lulian in-house laboratory
In-house laboratory · type & sample testing

§06 — Preguntas frecuentes

Lo que los compradores extranjeros preguntan antes de firmar el pedido.

¿Cuál es la diferencia entre U₀/U y Uₘ, y cuál debemos especificar?

U₀/U is the cable design voltage (phase-to-earth / phase-to-phase). Uₘ is the system maximum operating voltage. Per IEC 60502-2, cable U₀ must be ≥ the system highest phase-to-earth voltage under all operating conditions including earth-fault. Send the system nominal voltage AND the earth-fault factor and we confirm the cable class.

¿Pueden suministrar cable de 11 kV con marcado de cubierta BS 6622 para proyectos del Reino Unido?

Sí. Fabricamos según BS 6622 contra PO confirmado. El marcado de cubierta, la tarjeta de bobina y el formato del informe de ensayo de rutina siguen la práctica de inspección de servicios públicos del Reino Unido.

¿Cuál es el radio mínimo de curvatura durante la instalación?

Cable MV armado multimucleo: 12 × diámetro exterior para curvado único, 15 × D para curvado repetido. Mononuclear armado: 15 × D / 18 × D respectivamente (guía de instalación IEC 60502-2).

¿Pueden proporcionar inspección de terceros antes del envío?

Sí — SGS, BV, TÜV, Intertek y CCIC son los más comunes para pedidos de exportación. La inspección previa al envío normalmente cubre verificación de construcción, ensayo eléctrico de rutina, marcado y estado de la bobina.

¿Cuál es el plazo de entrega típico para un pedido de bobina MV de 20 km?

25–35 días hábiles para construcciones 6/10 kV y 8.7/15 kV en stock tras confirmación de PO; 40–55 días hábiles para clase 33 kV o construcciones específicas del proyecto.

Envíe el programa de cables. Confirmamos la construcción en 24 horas.

Share: voltage class, conductor material & size, core count, armour type, sheath material, installation method, total length and drum preference. The clearer the spec, the faster the technical confirmation.

RFQ por correo → sales@luliancable.comAbrir formulario de RFQ

Tensión (U₀/U)p. ej. 8.7/15 kV
ConductorCu class 2 · 3×185 mm²
ArmaduraSTA / SWA / AWA
CubiertaPVC ST2 / PE / LSOH
NormaIEC 60502-2
Longitud / bobina20 km · 4 bobinas
IncotermFOB Qingdao · CIF [puerto]