WHY LULIAN — THE FACTORY BEHIND THE CABLE

One factory owns every step your cable passes through.

01Own production, end to end

Drawing, stranding, insulation, armouring and sheathing run on our own lines in Liaocheng. Process parameters stay under our control — not a subcontractor’s.

02Tested on every drum

Routine tests on 100% of drums: conductor resistance, AC withstand, partial discharge ≤ 10 pC at 1.73 U₀. Test records ship with the cable.

03One range, 0.6/1 to 26/35 kV

LV, MV, control, fire-resistant, rubber and fiber optic cable from one works — mixed projects ship on one document set.

04Built for export projects

OEM marking, fumigated drums, third-party inspection and complete test documentation — packed for the port, not the warehouse.

2012
Established · own factory in Liaocheng
14+
Years in cable manufacturing
0.6–35 kV
Voltage coverage · LV to MV
OEM
Custom models · marking · packing

§02 — MEDIUM VOLTAGE CLUSTER

Pick your system voltage.

Each voltage page carries its own IEC 60502-2 insulation thickness, routine test voltage, partial-discharge point and impulse level — the values your inspector will check.

§03 — PROOF, NOT ADJECTIVES

A third-party type test report you can actually read.

Most factory sites say “strict quality control”. We publish the measured values: our WDZC-KYJY LSZH control cable passed a complete type test against GB/T 9330-2020 at a CNAS-accredited national lab.

80 %
Smoke transmittance · requirement ≥ 60 %
0.6 m
Bunched flame class C char height · limit 2.5 m
11.5 Ω/km
Conductor DC resistance · limit ≤ 12.1
3000 V
5-minute voltage test · no breakdown

Read the measured values

Cover of type test report No. 202521001018 issued by Qingdao Product Quality Testing Research Institute, CNAS L1184
Type test report No. 202521001018 · Qingdao Product Quality Testing Research Institute · CNAS L1184 · WDZC-KYJY 450/750 V 37×1.5

§04 — MANUFACTURING & TESTING

Real lines, real lab,
real routine tests.

Triple-extrusion dry-curing CCV for medium voltage, in-house electrical lab, routine test on every drum. Photos below are from our own facility in Liaocheng.

Aerial view of the Lulian cable factory campus, Liaocheng
Factory campusLiaocheng, Shandong
Wire drawing line — fine copper strands running through the drawing dies
Wire drawingConductor processing
Stranded copper conductor leaving the compaction die on the production line
Conductor strandingConductor
Insulated cores being laid up on the cabling machine
Cabling machineCore lay-up
Insulation extrusion — cable core passing through the extruder head
Extrusion & sheathingInsulation / sheath
XL-LED UV cross-linking equipment on the Lulian production floor
UV cross-linking lineIrradiation cross-linked wire
Wide view of the cable production hall
Production hallManufacturing
Laboratory optical measuring instrument and test bench at Lulian
LaboratoryType & sample testing
Stranding machines with copper spools
Operator at lineProduction

Nine steps from incoming conductor to tested, packed drum — photographed on our own floor in Liaocheng. Every cable leaves with a routine test report; ask for the factory audit package.

§05 — APPLICATIONS

Where our cable goes to work.

Six industries, each with its own conditions and selection logic — see the solution pages.

Utility distribution

6–35 kV feeders, ring mains and substation connections — the core of our export volume.

Industrial intake

Primary supply to factories, mines and process plants with own step-down substations.

Buildings & infrastructure

Building wire, LV power, LSZH and fire-resistant cable for tunnels, metros and public buildings.

Renewable energy

Wind farm collection, solar plant feeders and BESS connections at 10–35 kV.

Power grid communication

ADSS, OPGW and OPPC for transmission-line communication and protection signalling.

FTTH & telecom

GYTA / GYTS / GYTA53 duct and direct-buried optical cable up to 576 cores.

§07 — START THE CONVERSATION

Send the cable schedule.
We confirm the construction in 24 hours.

The clearer the specification, the faster the technical confirmation. If you only know the application, send that — we will propose the construction with the ampacity basis shown.

Voltage (U₀/U)e.g. 8.7/15 kV
ConductorCu / Al · 3 × 185 mm²
ArmourSTA / SWA / AWA
SheathPVC / PE / LSZH
StandardIEC 60502-2
Length & drums20 km · 4 drums
IncotermFOB Qingdao · CIF [port]