QUALITY & CERTIFICATIONS · CERTIFICATE LIBRARY

Certifications with numbers, scope and scans — not badges.

Every certification below states its number, its exact scope and its validity. Read the scope carefully: it tells you precisely which products each certificate covers. That is what your inspector will check — so we put it on the page first.

ISO 9001 · scan publishedCCC · building wire onlyType test 202521001018CNAS-accredited lab

§01 — Management systems

ISO 9001 / 14001 / 45001 — valid to 2027-12-26.

SystemCertificate No.ScopeIssued / Valid to
ISO 9001:2015 Quality102424Q0135R0SProduction of wire & cable within registered qualification scope2024-12-27 / 2027-12-26
ISO 14001 Environmental102424E0136R0SSame scope2024-12-27 / 2027-12-26
ISO 45001 Occupational H&S102424S0137R0SSame scope2024-12-27 / 2027-12-26
ISO 9001:2015 certificate No. 102424Q0135R0S for Shandong Lulian Cable, issued by CSIC, valid to 2027-12-26
ISO 9001:2015 · No. 102424Q0135R0S · scan
VERIFY IT

How to check a Chinese certificate

All three certificates are verifiable on the China National Certification and Accreditation Administration (CNCA) website at cnca.gov.cn using the certificate numbers above. We encourage buyers to verify before ordering.

Issuing body: CSIC Inspection Co., Ltd. (中理检验有限公司).

§02 — Product certification (CCC)

CCC covers our building wire range — and only that range.

China Compulsory Certification applies to specific product categories. Ours covers the 60227 IEC series PVC-insulated building wires and flexible cords. It does not extend to power cables or medium-voltage cables — any supplier claiming blanket “CCC certified cable” for MV products is misrepresenting the system.

CertificateNo.Covered productsValid to
CCC 752201401010574725260227 IEC 52 (RVV), 60227 IEC 53 (RVV), RVS flexible cords2028-12-04
CCC 753201401010574725360227 IEC 01 (BV), 02 (RV), 06 (RV), BVR building wires2028-12-04
CCC certificate 2014010105747252 for 60227 IEC 52/53 flexible cords
CCC 752 · scan
CCC certificate 2014010105747253 for 60227 IEC 01/02/06 building wires
CCC 753 · scan

§03 — Type test evidence

A complete third-party type test, values published.

Type test report No. 202521001018 cover, Qingdao Product Quality Testing Research Institute, CNAS L1184
Type test 202521001018 · CNAS L1184
ItemDetail
Report No.202521001018
ProductWDZC-KYJY 450/750 V 37×1.5 LSZH control cable
StandardGB/T 9330-2020 (+ IEC 60332-3C / 61034 / 60754)
LabQingdao Product Quality Testing Research Institute · CNAS L1184
Key resultsSmoke 80 % (req ≥ 60 %) · bunched flame C char 0.6 m (limit 2.5 m) · DC resistance 11.5 Ω/km (limit 12.1) · 3000 V/5 min no breakdown

Read the full measured-value tables →

§04 — How we test, drum by drum

Routine, sample and type tests — the three layers.

ROUTINE

Every drum, no exceptions

Conductor DC resistance, voltage withstand, sheath spark test, metallic screen check, construction dimensions, marking. The routine report travels with the drum.

SAMPLE

Every production batch

Partial discharge (MV), insulation thickness & eccentricity, armour coverage, mechanical properties of insulation and sheath.

TYPE

Every new construction

Bending + voltage, load cycling, impulse voltage — witnessed by CNAS-accredited third-party labs before a construction enters production.

§05 — Third-party inspection

Send your inspector — we will open the floor.

SGS, Bureau Veritas, TÜV, Intertek and CCIC inspections are routine for our export orders. Pre-shipment inspection typically covers construction verification against the PO, routine electrical tests, marking and drum condition. Factory audits are welcome with two weeks’ notice.

Request a factory audit →